Ribbon print Printer User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
15
Gap/Black Mark Calibration, Self-test and Dump Mode
While calibrate the gap/black mark sensor, printer will measure the label length, print
the internal configuration (self-test) on label and then enter the dump mode. To calibrate
gap or black mark sensor, depends on the sensor setting in the last print job.
Please follow the steps below to calibrate the sensor.
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do
during the 5 blinks)
The LED color will be changed as following order.
Amber Æ red (5 blinks) Æ amber (5 blinks) Æ green (5 blinks) Æ green/amber (5
blinks) Æ red/amber (5 blinks) Æ solid green
4. It calibrates the sensor and measures the label length and prints internal settings
then enter the dump mode.
Note:
Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE command prior to
calibrate the sensor.
For more information about GAP and BLINE command, please refer to TSPL2 programming
manual.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 22 23

Comments to this Manuals

No comments